Location: Home > Products > iGigE


Products

iGigE

Officially certified by AIA (Automated Imaging Association). AMD Tri-Mode Ethernet MAC used for controlling data-link layer. OKI’s GigE-Vision-UDP Offload Engine implemented, achieving high-speed transfer of GigE-Vision protocol packet. GV-UOE driver, MAC drive, GigE-Vision protocol stack are all implemented on MicroBlaze™; entire GigE Vision protocol processed in FPGA. Has boot loader program for implementing MicroBlaze management program from flash memory onto external memory.

Key Features
  • GigE-Vision-UDP Offload Engine
Target Markets
  • Broadcast
  • Industrial Scientific Medical

Device Family Support

  • Virtex-6 LX
  • Virtex-6 LXT

Device Implementation Matrix

Device utilization metrics for example implementations of this core. Contact provider for more information.

Family Device Speed Grade Tool | Version HW Validated? Slice LUT BRAM DSP48 CMT GTx Fmax (Mhz)
Spartan 6T Family XC6SLX45T -2 ISE 12.4,
ISE 12.4
Y 3957 3261 55 8 0 0 125

IP Quality Metrics Table

Deliverables
IP Formats available for purchase Netlist
Source Code Formats(s) Verilog
High-Level Model Included? N
Integration Testbench Provided Y
Integration Techbench Format(s) Verilog
Code Coverage Report Provided? Y
Functional Coverage Report Provided? Y
UCFs Provided? Y
Commercial Evaluation Board Available? N
FPGA used on board N/A
Software Drivers Provided? Y
Driver OS Support windows xp-8
Implementation
Code Optimized for AMD? Y
Custom FPGA Optimization Techniques None
Synthesis Software Tools Supported / version AMD XST
Static Timing Analysis Performed? Y
Standard IP Interface(s) Supported AXI-4
IP-XACT Metadata Included? N
Verfification
Is a documented verification plan available? Yes, document only plan
Test Methodology Directed Testing
Assertions Y
Coverage Metrics Collected Functional
Timing Verification Performed? Y
Timing Verification Report Available Y
Simulators supported Mentor ModelSIM
Hardware Validation
Validated on FPGA Y
Hardware validation platform used SP605
Industry standard compliance testing passed Y
Specific compliance test AIA's Machine Vision
Test date 2011-11-09 16:00:00.0
Are test results available? Y

Document download

Get Adobe Reader
Click here to download Adobe Reader.

Top of this page